MS-2000A/B High Frequency Mobile X-ray C-Arm System

MS-2000A/B High Frequency Mobile X-ray C-Arm Imaging System

MS-2000A/B mobile X-ray imaging system uses hi-frequency inverter device. The kV inverting frequency is 40kHZ, improving X-ray efficiency and reducing soft radiation dose largely. This inverter not only improves image quality but also minimize the X-ray damage to doctor and patient. The system integrates with imported image reinforcement and CCD video camera to get clear and perfect television image using much lower dose. Thanks to the flexible mechanical moving system, patient can be radioscopy and does not need to move body. Also the radioscopy can be operated in more complex conditions, like smaller space or complex targeted body part. This equipment applies to hospital surgery, sickroom, radiation room for X-ray patients for photograph inspection.

C-arm X-ray Radiographic Imaging System Features
Clinic Application
●Orthopedics (bone arthrosis shaping operation, bone arthrosis nailing, bone arthrosis imaging and radioscopy, urgent symptom reposition/fixing for bone wound)
●Gynecology uterus photography
●Normal surgery photography
●Urinary surgery (kidney bladder photography)
●Radiation department (kidney viscera photography, stomach & intestines radioscopy)
●Heart pacemaker installation
●Extracting impurities

Television System Characteristic
●Reinforcement Characteristic:
・ Central resolution≥48LP/cm;
・ Contrast 25:1;
・ DQE: 65%;
・Three View Ranges (9"/6"/4.5")
●Television System Specification:
・Television Scan Mode: 1250 Continuous Scan; Frequency: 75HZ;
・Camcorder: CCD 752(H)×582(V) (CCIR);
・Television Video Output: Full television signal; 1Vp-p (standard polarity);
・Image Format: 4:3
・Image Resolution: horizontal central resolution ≥12LP/cm (9” view range);
・Monitor horizontal resolution ≥800TVL;
・Image Brightness Definition: ≥ class 8;
・Contrast Sensitivity: ≤4%;
・Television Video Bind Width: ≥20M HZ;
・Camcorder 360°-rotate;

Control Parts Function
●Photograph
●Auto Clairvoyance
●Manual Clairvoyance
●Single Pulse Clairvoyance
●Enhanced Clairvoyance
●3 View-range Conversion
●Over-heated Alarm
●Over Radiation (over time radiation) Alarm

Image Processing
●4-level Recursion Noise Absorption
●Positive to Negative Film Reversal (black to white image reversal)
●Up to Down Image Reversal
●Mirrored Image
●Freezing Last Image
●Multiple Images Storage

Mechanical Specifications
●Focus screen length:
・2000A:900mm ・2000B:900mm/1000mm
●C arm arc depth:
・2000A:620mm ・ 2000B:890mm
●C arm vertical elevation distance:
・2000A:≥400mm ・2000B: ≥420mm
●C arm orbit slicling range:
・2000A:+90°~ -25°・2000B: +90°~ -45°
●C arm front-rear moving clistance: ≥200mm
●C arm vertical rotating renge: ≥±12.5°
●C arm horizontal rotating range: ≥±180°
●X-ray total filtration:2.7mmAL
●Distance from focus to skin: ≥200mm

Model

MS-2000A

MS-2000B

Power Consumption

3.5kW

5kW

Frequency

40kHz

40kHz

Hi-frequency Ripple

<1%

Total Filtration

>2.7mmAL

Photograph

kV/mA

40 ~110KV,60 ~ 30mA

40 ~120KV,80 ~ 40mA

mAs

5 ~ 160mAs

5 ~ 160mAs

Focal Point

1.5mm×1.5mm

0.6mm×0.6mm

Clairvoyance

kV/mA

40 ~ 110KV,0.5 ~ 5mA

40 ~ 120KV,0.5~5mA

Focal Point

0.6mm×0.6mm

0.3mm×0.3mm

Enhanced Clairvoyance

40 ~ 110KV,10mA

40 ~ 120KV,10mA

Anode Thermal Volume

30KJ(40kHU)

150KJ(200kHU)

Combined Machine-head Thermal Volume

500KJ(667kHU)

600KJ(800kHU)

Bind Limiter

Electric-powered Rotating Multi-leaf Aperture + Parallel 2-leaf Switch-on/Switch-off